LenzeÂ×´Ä8400±äƵÆ÷±¨¾¯OC6µç»ú¹ýÔØ¹ÊÕÏάÐÞ

LenzeÂ×´Ä8400±äƵÆ÷¹ÊÕϱ¨¾¯Î¬ÐÞ


1.Â×´Ä8400ʸÁ¿±äƵÆ÷ÊôÓÚÈ«ÐÂÒ»´úÇý¶¯²úÆ·£¬Ä£¿é»¯Éú²ú¡£8400ϵÁзÖΪ£º

¼òµ¥Çý¶¯BaselineϵÁÐ
±ê×¼Çý¶¯StatelineϵÁÐ
¸ßÐÔÄÜÇý¶¯HighlineϵÁÐ
ËÅ·þÇý¶¯ToplineϵÁÐ

2.¹¦ÂÊ·¶Î§£º0.37-400 KW¡£
Â×´ÄÊôÓÚ¶¥¼¶ÓÅÒìµÄÇý¶¯²úÆ·£¬×îÔç²ÉÓÃÄ£¿é»¯Éè¼ÆµÄ¹«Ë¾£¬IEC61508SIL3×îÐÂÅ·Ã˰²È«±ê×¼Éú²ú£¬½Ó¿ÚÇ¿º·£¬ÐÔÄÜÎȶ¨£¬Â״ĵIJúÆ·¹ýÔØÄÜÁ¦¶¼±È½ÏÇ¿£¬8400¹ýÔØÄÜÁ¦¸ß´ï180%£¬ÓжàÖÖÏÖ³¡×ÜÏßͨѶ·½Ê½£¬¿É×ÔÓÉÉèÖõŦÄÜ¿é±à³Ì½á¹¹¡£

3.¹ÊÕϱ¨¾¯Ìáʾ£º
Su02  Mains voltage is switched off µçÔ´µçѹ¹Ø±Õ
OH   Heatsink overtemperature É¢ÈȹýÈÈ
OH3  Motor temperature (X106) enabled µç»úζȣ¨X106£©¹ýÎÂ
OC5  Ixt overload  µçÁ÷¼«ÏÞ
OU   DC bus overvoltage Ö±Á÷ĸÏß¹ýѹ
LU   DC bus undervoltage Ö±Á÷ĸÏßǷѹ
OC2  Earth fault power section ½ÓµØ¹ÊÕÏ
NMAX   Maximum speed limit reached ×î´óËÙ¶ÈÏÞÖÆ
ID1      Error - motor data identification µç»úÊý¾Ýʶ±ð´íÎó
OC6   I2xt overload - motor  µç»ú¹ýÔØ
LP1   Motor phase failure µç»úÏàλ¹ÊÕÏ
SD3  Open circuit - feedback system ·´À¡ÏµÍ³¿ªÂ·
An01  AIN1_I < 4 mA Ä£Äâ¸ø¶¨Ð¡ÓÚ4ºÁ°²
CE04  MCI communication error  MCIͨѶ´íÎó
CE0F  MCI control word  MCI¿ØÖÆ×Ö
CE4   CAN Bus Off CAN×ÜÏ߹رÕ
CA06  CAN CRC error  CAN УÑé´íÎó
CA07  CAN Bus Warn CAN×ÜÏß¾¯¸æ
CA08  CAN Bus Stopped   CAN×ÜÏßÍ£Ö¹
CA0b  CAN Bus Live Time CAN×ÜÏß³¬Ê±
CA0F  CAN control word  CAN¿ØÖÆ×Ö³ö´í
CE1   CAN RPDO1  CANx_IN¼à¿ØÐÅÏ¢1
CE2   CAN RPDO2  CANx_IN¼à¿ØÐÅÏ¢2
CE3   CAN RPDO3  CANx_IN¼à¿ØÐÅÏ¢3
MCI1   Module is missing/incompatible Ä£¿é¶ªÊ§»ò²»¼æÈÝ
PS01   No memory module ÎÞÄÚ´æÄ£¿é
PS02   Par.set invalid Ãæ°å¸ø¶¨ÎÞЧ
PS03   Par.set device invalidÃæ°åÎÞЧ
PS04   Par.set Mci invalid Ãæ°å²é¿´ÎÞЧ
PS07   Par. memory module invalid Ä£¿éÄÚ´æ²ÎÊýÎÞЧ
PS08   Par. device invalid É豸²ÎÊýÎÞЧ
PS09   Par.format invalid  parÊý¾Ý¸ñʽÎÞЧ
dF25   CU RCOM error  CU°åÄÚ´æ´íÎó
RST   AutoTrip reset ×Ô¶¯¸´Î»ÌøÕ¢
dF50  Retain error ±£Áô´íÎó
dH10  Heatsink fan failure É¢ÈÈ·çÉȹÊÕÏ
US01 ¡¢US02 ¡¢US03 ¡¢US04    User-specific error with LS_SetErrorÓû§É趨µÄ´íÎ󱨾¯
Speed limit - feedback system ·´À¡ÏµÍ³ÏÞËÙ¹ÊÕÏ
I2xt overload - brake resistor  ɲ³µ¹ýÔØ¹ýÎÂ
Output frequency limited  Êä³öƵÂÊÏÞÖÆ
Switching frequency reduction  ¿ª¹ØÆµÂʹýµÍ
Maximum speed for Fchop  ³¬¹ýËÙ¶È
Maximum torque reached ¹ýת¾Ø£¨³¬ÔØ£©


×ªÔØÇë×¢Ã÷³ö´¦£ºÉϺ£Ñö¹âµç×ӿƼ¼×¨ÒµËÅ·þÇý¶¯Æ÷άÐÞ,ËÅ·þµç»úάÐÞhttp://www.rgrdmfo.cn/weixiu/weixiu5979.htm
¡¾ ÎÒÃÇÈ·±£¿ÉÒÔÐ޺òâÊԺøø¿Í»§£¡£¡£¡£¡¡¿ ËÅ·þÇý¶¯Æ÷άÐÞ,ËÅ·þµç»úάÐÞ,±äƵÆ÷άÐÞ
---ÁªÏµ·½Ê½£º
µç»°£º021-50157782
ÊÖ»ú£º15800396882
ÓÊÏ䣺shygdzi@163.com
ÁªÏµÈË£ºÕʤ
꿅᣼http://www.rgrdmfo.cn/

ÉÏһƪ£ºÂ×´Ä9400±äƵÆ÷¿ØÖÆËÅ·þµç»ú¿ÕÔØµçÁ÷Á¿Æ«´ó¹ÊÕÏάÐÞ
ÏÂһƪ£ºÎ÷ÃÅ×ÓÇý¶¯Æ÷³£¼û¹ÊÕÏÔ­Òò¼°¼ìÐÞ·½°¸
ÁªÏµÎÒÃÇ

CONTACT US

  • ËÅ·þµç»úάÐ޵绰

    13818985443 ¶Î¹¤

  • ±äƵÆ÷άÐ޵绰
  • ËÅ·þµç»úάÐÞµØÖ·

    ÉϺ£Êмζ¨Çø½­ÇÅÕòÏè½­¹«Â·1800ºÅ-888

ËÅ·þµç»úάÐÞ΢ÐÅ
 
  • Èç¹ûÄúÔÚÒòΪ»úÆ÷¹ÊÕÏάÐÞÐèÒªÕÒרҵάÐÞÈËԱάÐÞ»ò×Éѯ£¬»¶Ó­ÔÚ´ËÁôÑÔ£¬ÎÒÃǽ«¾¡¿ìÓëÄúÁªÏµ¡£
  • ÐÕÃû
  • µç»°
  • ¹ÊÕÏÄÚÈÝ
ÉϺ£Ñö¹âµç×ӿƼ¼ÓÐÏÞ¹«Ë¾°æÈ¨ËùÓÐ ICP±¸°¸ºÅ£º»¦ICP±¸16027027ºÅ-5 ÍøÕ¾µØÍ¼