άÐÞ·þÎñÏîÄ¿±¶¸£ËÅ·þÇý¶¯Æ÷³£¼û¹Ê´úÂëED43άÐÞ·ÖÎö
·¢²¼Õߣºmzx À´Ô´£ºÉϺ£Ñö¹â ·¢²¼Ê±¼ä£º2022-7-14
             
              ±¶¸£ËÅ·þÇý¶¯Æ÷³£¼û¹Ê´úÂëED43¼°Î¬ÐÞ·ÖÎö
ED43
Under voltage-DC link
ĸÏßµçѹ¹ýµÍ ¸ÄÉÆÍⲿÖ÷µç·¹©µç
F152
Initialization of the
feedback: Command
failed
·´À¡µçÀ³õʼ»¯´íÎó£¬Ò»°ãÓɸÉ
ÈÅÒýÆð¡£
¼õÉÙ¸ÉÈÅ£¬¼ì²é·´À¡ÏßÀ¼°½ÓÍ·
F19
Internal
Communication
ÄÚ²¿Í¨Ñ¶²»Á¼
1¡¢ ¼ì²éÊÇ·ñÓÐÇ¿¸ÉÈÅÔ´
2¡¢ ¼ì²éËÅ·þÄÚ²¿ÊÇ·ñÓлҳ¾,¿ÉÒÔ´µ·ç
´¦Àí.µç¹ñÐèÒªÁ¼ºÃÃÜ·â.
F415
Distributed clocks:
Process data sync
·Ö²¼Ê½Ê±ÖÓͬ²½ÐźÅÒì³£
1¡¢ ×öºÃ½ÓµØ´ëÊ©¡¢½µµÍ¸ÉÈÅ
2¡¢ Èç¹ûÊÇ CPU ÀûÓÃÂʹý¸ß£¬Çë½µµÍ
CPU ÀûÓÃÂÊ
3¡¢ ¼ì²é EtherCAT µçÀÂÓÐÎÞ½Ó²åËɶ¯
4¡¢ Ôö¼Ó DC Shift time
F2A0
Commutation error
1¡¢ ·´À¡µçÀ»ò¶¯Á¦µçÀÂËð»µ
»òÆÁ±Î²ã½ÓµØ²»Á¼
2¡¢ ÓëµÚÈý·½ËÅ·þÆ¥ÅäµÄ»»Ïò
½ÇУÕý´íÎó
3¡¢ PID ²ÎÊý²»ºÏÊÊ
4¡¢ ËÅ·þÇý¶¯Æ÷¹¦ÂÊÆ«Ð¡
5¡¢ ¼ÓËٶȺ͵çÁ÷·½Ïò²»Ò»ÖÂ
1¡¢ ¸ü»»·´À¡µçÀ»ò¶¯Á¦µçÀ£¬¸ÄÉÆÆÁ
±Î²ã½ÓµØ
2¡¢ ÖØÐ¼ì²é»»Ïà½Ç
3¡¢ µ÷Õû PID ²ÎÊý
4¡¢ Ìá¸ßËÅ·þ¹¦ÂÊ»ò½µµÍ¼ÓËÙ¶È
5¡¢ ¿ÉÒÔ¿¼ÂÇÐÞ¸Ä P-0-0069 ²ÎÊý
×ªÔØÇë×¢Ã÷³ö´¦£ºÉϺ£Ñö¹âµç×ӿƼ¼×¨ÒµËÅ·þÇý¶¯Æ÷άÐÞ,ËÅ·þµç»úάÐÞhttp://www.rgrdmfo.cn/weixiu/weixiu4978.htm
¡¾ ÎÒÃÇÈ·±£¿ÉÒÔÐ޺òâÊԺøø¿Í»§£¡£¡£¡£¡¡¿ ËÅ·þÇý¶¯Æ÷άÐÞ,ËÅ·þµç»úάÐÞ,±äƵÆ÷άÐÞ
---ÁªÏµ·½Ê½£º
µç»°£º021-50157782
ÊÖ»ú£º15800396882
ÓÊÏ䣺shygdzi@163.com
ÁªÏµÈË£ºÕʤ
꿅᣼http://www.rgrdmfo.cn/
ÉÏһƪ£ºÁ¦Ê¿Àֱ䯵Æ÷³öÏÖER08¹ÊÕÏ´úÂë´¦Àí·½·¨
ÏÂһƪ£ºÎ÷ÃÅ×ÓÇý¶¯Æ÷³£¼û¹ÊÕÏÔÒò¼°¼ìÐÞ·½°¸
    	ÁªÏµÎÒÃÇ
        
    CONTACT US
- 
            	
                13818985443 ¶Î¹¤
 - 
            	
               
             - 
            	
                ÉϺ£Êмζ¨Çø½ÇÅÕòÏè½¹«Â·1800ºÅ-888
 

	ÉϺ£Ñö¹âµç×ӿƼ¼ÓÐÏÞ¹«Ë¾°æÈ¨ËùÓÐ         ICP±¸°¸ºÅ£º»¦ICP±¸16027027ºÅ-5 
    
      
     ÍøÕ¾µØÍ¼
    
    
    